Case Communications 3200 Especificaciones Pagina 115

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 156
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 114
X723-300151 6-7 Issue 2
No. FAULT RELAYS LEDS ACTIONS N
SMAISNO
PSY RFI6ITCT
SAASAGSSE
MISC GROUP 9
1 Timeslot loop * 1 15
3 Map mismatch * 1 10
5 Rx. Atten. local 0
6 Rx. Atten. network 0
7 Network fail * 1 16
9 Module ? Status ? * 1 16 8
25 -48 battery fail * 7 16
26 Extern status 2 * 1 3
27 Extern status 3 * 1 7
28 Extern status 4 * 1 12
29 Extern status 5 * 1 16
30 Extern status 6 * 1 8
Self test * * ALL 7
MANAG GROUP 10
1 Config 1-14 0 5
15 Unconfigured * * * 1 5
16 Config self test 1 0
17 Config 1-14 corrupt * * * 1 5 6
31 Alarm event * * 1 10
32 Offline Unconf * 10
KEY:
RELAYS
P Prompt alarm.
S Service alarm.
SYS System alarm.
LEDS
1 Miscellaneous
2 Port 1 alarm
3 Port 2 alarm
4 Port 3 alarm
5 Port 4 alarm
6 Not primary sync source
7 PSU fault
8 System alarm
ACTIONS
RA Remote alarm sent.
MFA Multiframe alarm sent.
AIS Alarm Indication Signal sent.
16A Tslt 16 AIS sent.
SIG Signalling Fcodes set to MUX, FH on through timeslots.
TS Data Fcodes to MUX, FFH on through timeslots + TS0 spare bits to
'1'.
NCS Network Management Alarm Level